netANALYZER Real-Time Ethernet Analyzer
The netANALYZER is a tool for the simple analysis of Real-Time Ethernet networks. A capture-hardware for recording the telegrams in the network as well as a graphical user software for Windows with extensive analysis functions are included within the delivery. Of course, the netANALYZER hardware can also be used in combination with other analysis programs such as Wireshark.
With netANALYZER and the add-on software netANALYZER Scope, you can measure data at any time in the intuitive graphical interface with oscilloscope functions, e.g. process values, network load, communication events and telegram jitter, without affecting the Ethernet network or the PLC.
To narrow down the number of sporadic errors, netANALYZER box supports the autonomous operation without PC. A telegram can thus be recorded “quickly” in the field at the push of a button. For trouble shooting, the extensive trigger function enables the netANALYZER to remain in a plant for a while. If trigger events occur, the netANALYZER automatically generates telegram snapshots that can later be interpreted with the netANALYZER Scope software.
- Extensive analysis for Real-Time Ethernet systems
- Passive device without affecting the network or PLC
- Intuitive graphic display
- Station lists, alarms, process values, network load, and telegram jitter
- Endless recording with freely definable triggers
Product | Product name | NANL-B500G-RE |
Part number | 7313.100 | |
Description | netANALYZER portable Device with Gigabit Ethernet PC interface for Real-Time Ethernet and all 10/100BASE-TX Ethernet Networks (Stand-alone Device) | |
Function | Passive Ethernet analyzer for RT-Ethernet systems - analyzes the data in a communication link and captures the incoming Ethernet frames. Additionally, events of four digital inputs can be captured. | |
Power supply and current | Supply voltage | 24 V DC ±6 V DC |
Maximum current (typically) | 700 mA (at 24 V) | |
Typical power consumption | 16.8 W | |
Power connector | COMBICON, 3-pin, maximum permitted cable length: 3 m. Alternatively connector for barrel plug, maximum permitted cable length: 3 m. Only alternative use permitted! | |
System interface | Bus type / PC interface | Gigabit Ethernet RJ45 socket, required connection to the PC‚ UPLINK 1 Gb/s: Ethernet RJ45 socket (1 Port) |
Recording interface | USB 2.0 (hard disc or memory stick), max. 500 mA or external supply | |
Autonomous operation | Data rate approx. 50 % network load when recording on one TAP | |
Measurement interface | Connector | 4 x RJ45 socket, channels/ports: 2/4 communication channels with integrated TAP (TAP A, TAP B), and each with two ports for capturing data in both directions (together 4 Ports: Port 0 to Port 3) |
Digital signals | 4x GPIO In-/Output 3.3 V and 24 V for capturing digital signals or using as trigger output | |
Time stamp | ± 5 ns measurement accuracy, 1 ns resolution | |
Operating elements | Switch/Button | Power Switch, REC Button to enable data recording in autonomous mode |
Permitted ambient conditions | Ambient temperature range for operation | 0 °C ... +55 °C (Air flow during measurement: 0,5m/s) |
Ambient temperature range for storage | -10 °C ... +70 °C | |
Humidity range | 10 % … 95% relative humidity, no condensation permitted | |
Pollution degree | The device must be used in a pollution degree 2 environment. | |
Altitude | 0 m … 2000 m | |
Device | Dimensions (L x W x H) | 115 x 62 x 173 mm |
Weight | approx. 820 g | |
Conformity | RoHS | Yes |
Conformance with EMC directives | CE sign | Yes |
UKCA sign | Yes | |
Emission | EN IEC 61000-6-4 / BS EN IEC 61000-6-4 | |
Immunity | EN IEC 61000-6-2 / BS EN IEC 61000-6-2 | |
Electrostatic discharge (ESD) according to EN IEC 61000-4-2 / BS EN IEC 61000-4-2 (Air discharge method) | ± 8 kV, Criterion B | |
Electrostatic discharge (ESD) according to EN IEC 61000-4-2 / BS EN IEC 61000-4-2 (Contact discharge method) | ± 6 kV, Criterion B | |
Radiated RF, according to EN IEC 61000-4-3 / BS EN IEC 61000-4-3: 80-1000 MHz, 10 V/m, 80 % AM / 1 kHz | Criterion A | |
Radiated RF, according to EN IEC 61000-4-3 / BS EN IEC 61000-4-3: 1.0-2.7 GHz, 10 V/m, 80 % AM / 1 kHz | Criterion A | |
Fast transient interferences (Burst) according to EN IEC 61000-4-4 / BS EN IEC 61000-4-4 (Communication and data lines) | ± 2.2 kV, Criterion B | |
Surge voltage, according to EN IEC 61000-4-5 / BS EN IEC 61000-4-5 (Communication and data lines) | 1 kV, Criterion A | |
Conducted RF, according to EN 61000-4-6 / BS EN IEC 61000-4-6: 0,15-80 MHz, 10 V, 80 % AM / 1 kHz | Criterion A |
Description |
Order number |
NANL-B500G-RE - netANALYZER Real-Time Ethernet Analyzer, Box | 7313.100 |
LIC/NANL/SA - NANL-B500G-RE add-on, autonomous operation without PC | 8582.060 |
Operating instruction manual | Versie: V03 |
User manual | Versie: Rev/ 27 |