MODBUS to PROFIBUS PA Gateway
Direct PROFIBUS PA Segment Integration into Modbus TCP Control Systems
MODBUS to PROFIBUS PA Gateway
Direct PROFIBUS PA Segment Integration into Modbus TCP Control Systems
- Re-use of Existing Power Conditioners in Technology Upgrade Projects
- No PROFIBUS DP Intermediate Segment required
- Prepared for Integration in Standard Engineering and Plant Asset Management Tools
- Simple replacement of installed PROFIBUS DP/PA segment couplers
- Re-use of existing PROFIBUS PA segments without requiring modification
- Support of PROFINET redundancy for increased reliability
- Direct Connectivity to PROFIBUS Segments
- Acting as Modbus Server and PROFIBUS PA Master
- Support of up to 4 PROFIBUS PA segments
- Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
- Included CommDTM allowing use in FDT/DTM frame applications
- EDD-based device parametrization using Siemens Simatic PDM
Vraag direct een offerte aan!
MODBUS to PROFIBUS PA Gateway
Hardware | |
Processor | Altera Cyclone V SoC with dual-core ARM Cortex-A9 |
Status LEDs (Gateway) | PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update) |
Status LEDs (Fieldbus) | SF (system fault), BF (bus fault) |
Interfaces and Connectors | |
Ethernet | 2 * IEEE 802.3 100BASE-TX / 10BASE-T, managed Ethernet switch for daisy chain totpology Connectors: RJ45 Protocol: Modbus TCP Server RESTful API interface for device configuration |
PROFIBUS PA | Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”), Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC ... 32 VDC, current consumption 10 mA, Connectors: 3-position screw connection, galvanically isolated |
Physical Properties | |
Dimensions (H x W x D) | 100 mm x 35 mm x 105 mm |
Weight | About 0.25 kg |
Power Supply | 18 VDC ... 32 VDC, SELV/PELV power supply mandatory Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on) No power supply to PROFIBUS PA segments through pnGate PA |
Operating / Storage | -40 °C ... +70 °C / -40 °C ... +85 °C |
Temperature | (see detailed mounting description in user manual) |
Relative Humidity | 10 % ... 95 %, non-condensing |
Cooling | Convection, no fan |
Coating | Conformal coating based on ANSI / ISA-S71.04 G3 |
Mounting | DIN rail 35 mm |
Protection Class | IP20 |
Description |
Order number |
mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices) | GCA-EL-024802 |
mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices) | GCA-EL-024804 |
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices) | GCA-AL-024602 |
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices) | GCA-AL-024604 |
pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane | GCA-AL-024605 |
pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485) | GCA-AN-024608 |
vraag meer informatie over toepassingen aan via ons contactformulier.