MODBUS to PROFIBUS PA Gateway

Direct PROFIBUS PA Segment Integration into Modbus TCP Control Systems

MODBUS to PROFIBUS PA Gateway

Direct PROFIBUS PA Segment Integration into Modbus TCP Control Systems

  • Re-use of Existing Power Conditioners in Technology Upgrade Projects
  • No PROFIBUS DP Intermediate Segment required
  • Prepared for Integration in Standard Engineering and Plant Asset Management Tools
  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS PA segments without requiring modification
  • Support of PROFINET redundancy for increased reliability
  • Direct Connectivity to PROFIBUS Segments
  • Acting as Modbus Server and PROFIBUS PA Master
  • Support of up to 4 PROFIBUS PA segments
  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Hardware
ProcessorAltera Cyclone V SoC with dual-core ARM Cortex-A9
Status LEDs (Gateway)PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
Status LEDs (Fieldbus)SF (system fault), BF (bus fault)
Interfaces and Connectors
Ethernet2 * IEEE 802.3 100BASE-TX / 10BASE-T, managed Ethernet switch for daisy chain totpology Connectors: RJ45 Protocol: Modbus TCP Server RESTful API interface for device configuration
PROFIBUS PAUp to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”), Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC ... 32 VDC, current consumption 10 mA, Connectors: 3-position screw connection, galvanically isolated
Physical Properties
Dimensions (H x W x D)100 mm x 35 mm x 105 mm
WeightAbout 0.25 kg
Power Supply18 VDC ... 32 VDC, SELV/PELV power supply mandatory Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on) No power supply to PROFIBUS PA segments through pnGate PA
Operating / Storage-40 °C ... +70 °C / -40 °C ... +85 °C
Temperature(see detailed mounting description in user manual)
Relative Humidity10 % ... 95 %, non-condensing
CoolingConvection, no fan
CoatingConformal coating based on ANSI / ISA-S71.04 G3
MountingDIN rail 35 mm
Protection ClassIP20

Description

Order number

mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices)GCA-EL-024802
mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices)GCA-EL-024804
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices)GCA-AL-024602
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices)GCA-AL-024604
pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplaneGCA-AL-024605
pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485)GCA-AN-024608
vraag meer informatie over toepassingen aan via ons contactformulier.